LC1D12N7Main Range TeSys Product name TeSys D Product or component type Contactor Device short name LC1D Contactor application Motor control Resistive load Utilisation category AC 1 AC 4 AC 3 Poles description 3P Power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25 400 Hz Power circuit: <= 300 V DC [Ie] rated operational current 25 A (at <60 C) at <= 440 V AC AC 1 for power circuit 12 A (at <60 C) at <= 440 V AC AC
Main
| Range | TeSys |
| Product name | TeSys D |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-1 AC-4 AC-3 |
| Poles description | 3P |
| Power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Motor power kW | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power HP (UL / CSA) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 415 V AC 50/60 Hz |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified |
| Electrical durability | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V |
| Power dissipation per pole | 0.36 W AC-3 1.56 W AC-1 |
| Safety cover | With |
| Mounting support | Plate Rail |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
| Product certifications | UL GOST BV CCC CSA DNV RINA GL LROS (Lloyds register of shipping) |
| Connections - terminals | Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end |
| Tightening torque | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat √ò 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat √ò 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
| Operating time | 12...22 ms closing 4...19 ms opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Maximum operating rate | 3600 cyc/h 60 °C |
Complementary
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C) |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C) 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm for signalling circuit |
Environment
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Pollution degree | 3 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -60…80 °C |
| Permissible ambient air temperature around the device | -40…70 °C at Uc |
| Operating altitude | 3000 m without |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 0.325 kg |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| REACh free of SVHC | Yes |
| EU RoHS Directive | Under investigation |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.7 ★★★★★
Based on 18 reviews
Sort
Product Reviews
★★★★★ 5
Great for sensitive skin
Size: 2 Fl Oz (Pack of 1)
I have extremely sensitive skin and recently found out my skin hates the sun due to my autoimmune issues. This sunscreen doesn't break my skin out, keeps me from getting sunburnt and doesn't have a bunch of fragrance. This travel size has been perfect for throwing in my bag for a day at the baseball park or beach. This is a non greasy and no whitecast spray that has a high spf too. I highly recommend it.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 6, 2026
★★★★★ 5
Apply BEFORE leaving the house!
Size: 6 Fl Oz (Pack of 1)
I have fair (freckle don’t tan, burn easily then peel and back to white) and sensitive skin. So does my son. I live on the coast, in a southern state and vacation in the Caribbean often. After too many years of getting burned, I finally found Coola a couple years ago. It has revolutionized my time in the sun.
Here’s the thing tho. If you don’t apply it properly, it’s not gonna work. If you’re looking for something to put on AT the pool or beach, go for something else (with zinc oxide preferably). If you’re willing to take 5 mins before you go to do it, you’ll be very happy. Kids especially are hard enough to get covered before they see water anyway!
Here’s some tips:
Spray everyone OUTSIDE (even the unscented can overwhelm inside, and you really don’t need to be breathing in ANY sunscreen)
DO NOT USE ON FACE. It will burn your eyes when you sweat/swim. Choose a cream or face stick.
Spray until skin is wet. You’re not looking for a light misting, you’re going for full coverage. The can can sound like it’s spraying, but if you don’t see the product on the skin, you’re gonna get burned.
Give it 5 mins to dry before putting on shirts/cover ups.
Reapply between 2 & 3 hours of water exposure. (We usually dry off, respray, then have a snack or lunch) Give it 15 - 20 mins to soak in before you hit the water again.
I’ve found a 6oz can will usually take care of two adults and a child for the day (initial and resprays). It’s a tad expensive, so we use Coola on days we plan to be out for more than a couple hours, or every day in the Caribbean, since the sun is SO intense.
The 2oz is ‘touch up’ sized. It may take care of a child’s initial spray, but I’ve found it more suited for adding additional spray to areas that feel a bit crispy, rather than using it on a single application.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 20, 2022
★★★★★ 5
Dries fast and clean
Size: 2 Fl Oz (Pack of 1)
Dries without greasy residue
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 27, 2026
★★★★★ 1
Toxic ingredients
Size: 2 Fl Oz (Pack of 1)
There are endocrine disruptors in here that are harmful to your health. I nearly got to the point of being disabled from endocrine issues. Has ingredients that ruin fertility, raise risk of cancer, and ruin your endocrine system. I hope these brands can take these ingredients out and begin to care about consumers health.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 21, 2026
★★★★★ 5
Best Baby Sunscreen ☀️
Size: 6 Ounce (Pack of 2), Style: SPF 50 Spray
Putting sunscreen on a one year old is never an easy task. So I learned very quickly that the spray was a must. I’ve tried several different kinds and have had issues with eye irritation because I’m sure as y’all all know (that I definitely did not know) the first thing they do when you put sunscreen on their face is rub it immediately in their eyes. Although this one is not completely irritation free, I have noticed much less irritation to her eyes (or maybe she’s finally learning not to rub her eyes after I put it on idk 🤷🏼♀️). Regardless this is a great safe, easy to apply sunscreen for babies!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 18, 2026