MGB-L2B-PNC-L-123012MGB LH Evaluation Module and Bus Module MGB L2 PN (Guard Locking by Solenoid Force) with 4 Control Elements, Push Pull Plug Evaluation Module and Bus Module Feature(s) Guard locking with guard lock monitoring Emergency stop according to ISO 13850, illuminated 3 illuminated pushbuttons Push pull plug Pre assembled on mounting plates Integrated Profinet RT switch Multicode Specifications Electrical connection values Connecting cable Ethernet Profinet I
Evaluation Module and Bus Module
Feature(s)
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 illuminated pushbuttons
- Push-pull plug
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Multicode
Specifications
Electrical connection values
|
Connecting cable |
|
|
Ethernet |
Profinet I/O cable, at least cat. 5e |
|
Rated insulation voltage Ui |
75 V |
|
Rated impulse voltage Uimp |
0.5 kV |
|
EMC protection requirements |
In accordance with EN 61000-4 and EN 61326-3-1 |
|
maximum feed-in current in the connection block |
|
|
X1, X2 |
max. 4000 mA |
|
Safety class |
III |
|
Current consumption |
max. 600 mA |
|
Transponder coding |
Multicode |
|
Degree of contamination (external, according to EN 60947-1) |
3 |
|
|
Power supply X1 |
|
Fuse |
|
|
external |
min. 1 A slow blow |
|
Operating voltage DC |
|
|
L1 |
24 V DC -15% ... +10% |
|
Auxiliary voltage DC |
|
|
L2 |
24 V DC -15% ... +10% |
|
|
Power supply X2 |
|
Operating voltage DC |
|
|
L1 |
24 V DC -15% ... +10% |
|
Auxiliary voltage DC |
|
|
L2 |
24 V DC -15% ... +10% |
Mechanical values and environment
|
Connection type |
|
|
|
Push-pull power |
|
for enabling switch |
Plug connector RC12 |
|
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e |
Push-pull RJ45 |
|
|
Push-pull power |
|
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e |
Push-pull RJ45 |
|
Installation orientation |
Door hinge DIN left |
|
Switching frequency |
0.25 Hz |
|
Mechanical life |
|
|
|
1 x 10⁶ |
|
in case of use as door stop, and 1 Joule impact energy |
0.1 x 10⁶ |
|
Response time |
|
|
Enabling switch |
max. 250 ms Turn-off time |
|
Bolt position |
max. 550 ms Turn-off time |
|
Guard locking |
max. 550 ms Turn-off time |
|
Emergency stop / machine stop |
max. 250 ms Turn-off time |
|
Door position |
max. 550 ms Turn-off time |
|
Shock and vibration resistance |
Acc. to EN IEC 60947-5-3 |
|
Degree of protection |
IP54 |
|
Ambient temperature |
|
|
with UB = 24 V DC |
-20 ... +55 °C |
|
Material |
|
|
Housing |
Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
|
Locking force FZh |
2000 N |
|
Guard locking principle |
Open-circuit current principle |
Downloads
Additional Information
| Device | Module |
| Type | Evaluation | Bus |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy