LT4706BAMain Range TeSys Product name TeSys LT Product or component type Electronic over current relay Device short name LT47 Device application Protection Relay application Locked rotor, mechanical jamming I > 3 x Isetting Overload Imax > Isetting Sensitivity to phase failure [Us] rated supply voltage 24 V AC 24 V DC Thermal protection adjustment range 0. 56 A [Ui] rated insulation voltage Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC
Main
| Range | TeSys |
| Product name | TeSys LT |
| Product or component type | Electronic over current relay |
| Device short name | LT47 |
| Device application | Protection |
| Relay application | Locked rotor, mechanical jamming I > 3 x Isetting Overload Imax > Isetting Sensitivity to phase failure |
| [Us] rated supply voltage | 24 V AC 24 V DC |
| Thermal protection adjustment range | 0.5…6 A |
| [Ui] rated insulation voltage | Power circuit: 600 V AC conforming to CSA Power circuit: 600 V AC conforming to UL Power circuit: 690 V AC conforming to IEC 60947-4-1 |
Complementary
| Network frequency | 50...60 Hz |
| Mounting support | Rail |
| Tripping threshold | 0.5...5 A |
| Electromagnetic compatibility | Resistance to electrostatic discharge: 8 kV in open air conforming to IEC 61000-4-2 Resistance to electrostatic discharge: 6 kV in direct mode conforming to IEC 61000-4-2 Conducted emission: class A conforming to EN 55011 Immunity to electromagnetic interference: 10 V/m conforming to IEC 61000-4-3 Immunity to fast transients: 2 kV conforming to IEC 61000-4-4 Surge withstand: 6 kV conforming to IEC 61000-4-5 Conducted HF disturbances: 10 V conforming to IEC 61000-4-6 |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 3 A for signalling circuit |
| Associated fuse rating | 3 A gG for signalling circuit 3 A BS for signalling circuit |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Time range | 1...120 s - control type R-time 0.3...30 s - control type O-time |
| Local signalling | 1 LED (green) 1 LED (red) |
| Control type | Automatic: reset |
| Connections - terminals | Signalling circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: lugs-ring terminals - external diameter: 7 mm |
| Tightening torque | Signalling circuit: 1.7 N.m M3.5 |
| Height | 70.3 mm |
| Width | 71 mm |
| Depth | 77.2 mm |
| Net weight | 0.192 kg |
Environment
| Standards | IEC 60255-6 IEC 60947 |
| Product certifications | UL CSA |
| Protective treatment | TH conforming to IEC 60068 |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to VDE 0106 |
| Ambient air temperature for operation | -25…60 °C without derating conforming to IEC 60947-4-1 |
| Ambient air temperature for storage | -30…80 °C |
| Operating altitude | 2000 m |
| Mechanical robustness | Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 4 gn conforming to IEC 60068-2-6 |
| Dielectric strength | 2 kV at 50 Hz conforming to IEC 60255-5 |
Offer Sustainability
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.6 ★★★★★
Based on 18 reviews
Sort
Product Reviews
★★★★★ 5
10/10
Format: Paperback
Another perfect example of how great Loeb and Sale nail Batman
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 29, 2025
★★★★★ 5
I Loved it!
Format: Paperback
Amazing
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 6, 2025
★★★★★ 4
Long Halloween Prequel
Format: Paperback
We can see here the first try of what would become a legendary duo for Batman, and it's a very decent one. These 3 stories are inspired by 3 different themes: Fear, Madness, and Ghosts. Personally, Madness was the best one; I've always found the Mad Hatter e very curious villain in this world and the tie-in to Bruce's childhood is a nice feat. The Ghosts story feels very rushed once the second spirit visits (Joker), so it lacks depth in the analysis it's trying to do emulating 'A Christmas Carol'.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 27, 2023
★★★★★ 5
Great book
Format: Paperback
A must read
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 7, 2024
★★★★★ 5
Just Classic Batman!
Format: Kindle
I don't think I have read these tales in about 20 years. I miss Jeph Loeb on Batman. While I think he put a great spin on Superman, Loeb set the foundation for all of the visual medium for Batman. This collection of three one-shots gives us good Scarecrow and Mad Hatter Halloween stories. My favorite was the final story with a retelling of A Christmas Carol but Halloween and Batman.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 6, 2021