SKU: 6059959993

UA-Glo® Beta-Gal Luminescence Detection Kit

Sale price$69.30 Regular price$77.00
Save 10%

Pay in installments of $19.25 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Sep 9 - Sep 14

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

UA-Glo® Beta-Gal Luminescence Detection KitProduct Specification Synonyms Beta Gal Stability & Storage Dry ice transportation. Store in a dark place at 20 or below. It is recommended to store for a long term (more than 2 months) at 80, with a validity period of 12 months. After the first use, it is suggested to aliquot the reagent and store it in a dark place at 20 or below. Freezing and thawing should not exceed 3 times. Background Beta galactosidase (Beta Gal) is one of the earliest reporter

Product Specification


Synonyms Beta-Gal
Stability & Storage

Dry ice transportation. Store in a dark place at -20℃ or below. It is recommended to store for a long term (more than 2 months) at -80℃, with a validity period of 12 months. After the first use, it is suggested to aliquot the reagent and store it in a dark place at -20℃ or below. Freezing and thawing should not exceed 3 times.

Background

Beta-galactosidase (Beta-Gal) is one of the earliest reporter genes and has a wide range of applications. Traditional methods for detecting Beta-Gal include colorimetric and fluorescence methods, but both have disadvantages such as non-homogeneous detection or low sensitivity. The UA-Glo® Beta-Gal Luminescence Assay Kit uses Lu-Gal as the substrate. After Beta-Gal cleaves Lu-Gal, it generates luciferin, the substrate of luciferase. Luciferin is then acted upon by luciferase to produce luminescence, which is detected. The intensity of the luminescence is directly proportional to the expression level of Beta-Gal. The UA-Glo® Beta-Gal Luminescence Assay Kit is a homogeneous detection reagent. It can be detected as soon as 0.5 hours after adding the reagent, and the signal intensity is very stable, remaining largely unchanged within 3 hours. It is particularly suitable for high-throughput screening of compounds.

Components

The components and specifications of the Beta-Gal luminescence detection kit are as follows

Beta-Gal Test reagents

Count the number of holes in the 96-well plate

Count the number of holes in the 384-well plate

10 ml

100 

500 

100 ml

1,000 

5,000 

10 x 100 ml

10,000 

50,000

Protocol

  1. Seed cells expressing Beta-Gal at an appropriate density in white, clear-bottom 96-well or 384-well cell culture plates. Serum, such as FBS, may contain mammalian Beta-Gal, so it is recommended to use heat-inactivated FBS (56°C, 0.5 hr) to prepare the complete medium for cell seeding. Within the same plate, it is advisable to include wells with cells that do not express Beta-Gal or wells with only complete cell culture medium as background controls for Beta-Gal detection. The background readings can be used to correct the experimental readings.

  2. Perform cell treatment according to experimental requirements, followed by Beta-Gal detection.

  3. Take out the Beta-Gal detection reagent, allow it to completely dissolve, and equilibrate to room temperature (22°C–25°C). Invert gently to mix thoroughly.

  4. Remove the cell culture plate and equilibrate it to room temperature (22°C–25°C). The luciferase reaction is sensitive to temperature changes. Both the reagent and test samples/plates should be equilibrated to room temperature, and the temperature should remain constant (±1°C) throughout the testing process.

  5. Add Beta-Gal detection reagent equal in volume to the culture medium in each well of the cell culture plate. For example, add 100 µl of detection reagent to 100 µl of culture medium.

  6. Shake the plate for 30 seconds to mix thoroughly, then incubate in the dark for 30 minutes before performing luminescence detection. Readings can be taken within 3–5 hours.

  7. Data processing: For most experiments, the raw data can be used directly for subsequent calculations. If the background is high, subtract the background readings (from cells without Beta-Gal expression or complete medium-only wells) from the experimental readings, and use the background-corrected data for further calculations.

Guidelines

1. Different batches should not be mixed.
2. Without strict verification, it is not recommended to change the dosage of reaction reagents.
3. For research purposes only.

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 6059959993

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.3 ★★★★★
Based on 25 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
B
Verified Purchase
Bob F.
Chelsea, US
★★★★★ 4
Does Not Fit
Size: 2" x 10" x 11"
This does not fit the 2024 Accord Sport Hybrid. It is approximately 1/4 inch too wide on each side (1/2 inch total), will not fit in the opening. Car was entered into the system and purchase page says this is correct and will fit.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 22, 2026
W
Verified Purchase
William
Bozeman, US
★★★★★ 5
Fit
Size: 8.8" x 9.3" x 1.1"
Product looks and works well
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 7, 2026
C
Verified Purchase
Chris G
Louisville, US
★★★★★ 5
Easy installation
Size: 8.8" x 9.3" x 1.1"
It fit my 2011 Honda accord coupe 👍🏼
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 15, 2026
T
Verified Purchase
Teresa
Phoenix, US
★★★★★ 5
Works great
Size: 8.8" x 9.3" x 1.1"
Good filter
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 15, 2025
T
Verified Purchase
tonyb
Grantham, US
★★★★★ 5
Fit as stated
Size: 8.8" x 9.3" x 1.1"
Perfect fit for my 2013 Honda and price was great
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 28, 2025

recommand products