Pay in installments of $46.03 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 23 - Jul 28
For Your Every Summer RSVP, with Code: SUMMER15
Description
Rat PER1 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20
Product Specification
| Usage |
Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37℃ constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant and centrifuge at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing. Cell Supernatant: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse the tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed. Preparation before testing: 1. Please remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Preparation of gradient standard working solution: Add 1mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, and then gently mix (concentration is 10ng/mL). Then dilute to the following concentrations: 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.3125ng/mL, 0.15625ng/mL, and 0ng/mL. Serial dilution method: Take 7 EP tubes and add 500uL of universal diluent to each tube. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this step to mix thoroughly. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit utilizes a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Period Circadian Protein 1 (PER1) capture antibody. After incubation and washing, the assay is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of Period Circadian Protein 1 (PER1) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Rat | |||||||||||||||||||||||||||||||||
| Synonym | Rat Period Circadian Protein 1 ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | PER1 (Period Circadian Regulator 1) is a protein-coding gene. Disorders associated with PER1 include Advanced Sleep Phase Syndrome and Rem's Sleep Behavior Disorder. Pathways associated with PER1 include metabolic state and the circadian oscillator, as well as the HIF1α pathway. Gene Ontology annotations associated with this gene include transcription factor binding and sequence-specific DNA binding to the cis-regulatory region of RNA polymerase II. An important homologue of this gene is PER2. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.156-10 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Serum, plasma, cell supernatant, tissue homogenate, etc. |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.3 ★★★★★
Based on 23 reviews
Sort
Product Reviews
★★★★★ 5
Great privacy option for townhome deck!
Color: White, Size: 6 Panel, Color: White, Size: 6 Panel
Deck privacy! I wanted a way to add some privacy to my second floor townhome deck. It’s been holding up well and doesn’t look junky! I used zip ties on one end so I can open and close it as I wish. Great solution to living in close quarters to your neighbors! I purchased the six panel and it’s a perfect size
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 3, 2026
★★★★★ 4
Flimsy
Color: Beige, Size: 8 Panel
It’s thinner than what I thought and flimsy.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 2, 2026
★★★★★ 5
Good product, poor directions.
Color: Black, Size: B-88''W-4 Panel
The quality of the product was better than most at this price. The directions could have been much better even though I have an engineering background.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 1, 2025
★★★★★ 4
Nice partition for my basement
Color: Beige, Size: B-102''-3 Panel
This 3-panel room divider showed up well-packaged with all the parts and even a little tool for putting it together. The instructions were easy to follow, and while one person can definitely assemble it, having two makes it quicker and less frustrating.
It does exactly what I needed—gives quick, easy coverage in an open area. I'm using it in my basement to hide the furnace and water heater, and it works great for that. It looks nice overall, but I picked the beige fabric (which is really more of a tan), and the black frame makes it stand out more than I’d like. A white or lighter frame would’ve blended better. Not sure that I would use it anywhere besides the basement
It’s lightweight and pretty sturdy. The wheels make it easy to move, but it does get a bit wobbly, and the panel clips need to be readjusted every time you roll it somewhere new. Still, for the price, it’s a solid buy. I’m happy with it and planning to order another one.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 21, 2025
★★★★★ 5
Fantastic
Color: Beige, Size: A-132''W-6 Panel
I am perennially in the process of rearranging, reorganizing, getting ready for yard sales, changing the functions of various rooms, moving everything out of a room to do a deep clean, etc, which means that there is always SOME part of my house, if not the entire thing, that is a disaster zone. Having someone knock on my door triggers a "duck and cover" reflex because it's so embarrassing for anyone to see that I live like this. (I *feel* like I don't, really, because I know that all the various stages are all temporary, but when there's always something temporary going on, it might as well be permanent, you know?)
So THANK HEAVENS for a room divider that is not only large enough to divide my uncomfortably long den in half the long way so I can shove all the messy parts up against the back wall -- that is not only simple and attractive and neutral and (this is important) NOT BLACK because I have multiple pets and anything black in this house will be pet-hair-colored within 20 seconds -- that not only has **SIX** panels for lots of options of how I want to divide the space/s -- but is also on WHEELS.
Someone out there really does love me, it's true!
The panels are stable *enough* - I'm not going to lie and say that nothing is going to knock them over, because I have some balance issues, and I also have cats, and both of those circumstances has resulted in a mess on at least one occasion. But in the cats' defense, they've never dealt with a room partition that didn't hang from the ceiling before; and in my defense, I just grabbed the first thing I could reach on the way down. Not the product's fault in either case.
Assembly was a little dicey as I am currently in **bilateral** (oh yes, that's fun) wrist braces, so I had to give up until I had help. But I think if you're able-bodied, you shouldn't have any difficulty.
The only down side is, now that I've hidden away all the mess so I can break out the holiday decorations, you know what happens next, right?? That's right... the PERMA-MESS ZONE. Oh no.
Oh well.
Full item name: Room Divider 132''W Wall Divider for Room Partition (Heavy Duty Base) 6 Panel Partition Room Dividers, Freestanding Room Divider Screen Separation W/Wheel Folding Privacy Screen Panel Space Separator
(six panels, beige)
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 1, 2025